Sign In | Join Free | My ledscreensign.com |
|
Brand Name : E+H
Model Number : PMP71
Certification : CE
Place of Origin : China
MOQ : 1
Payment Terms : L/C,D/A,D/P,T/T,Western Union
Supply Ability : 100pcs/Month
Delivery Time : 5-8 works day
Packaging Details : carton
Thread : G1/4 Male and female All can be
Using Range : differential pressure
Interface Size : M20*1.5
Turndown Ratio : 100:1
Sensor Material : stainless steel 316
Measuring Range : 0~20mpa
Modle : BP93420D-IIIA
Long Term Stability : 0.1%F.S/Y(≤2000KPa)
Accuracy Class : ± 0 . 075~±0 .2 %
Pressure Port : G1/4, G1/2 1/4NPT, 1/2NPT and others
Model Numbe : SLK-13
Positioning Accuracy : ±0.1%
Types : Intelligent pressure transmitter
Product Description
Cerabar PMP71 Digital Pressure Measurement Transmitter Pressure Transmitters For Measuring Liquids And Gases
The Cerabar PMP71 digital pressure measurement transmitter uses a metal diaphragm and is mainly used in the process industry to measure the pressure, liquid level, volume, and mass of liquids and gases. PMP71 is designed specifically for high-pressure measurement applications, with a maximum working pressure of up to 700ba. It comes with a quick setting function and adjustable range. The design complies with the IEC61508 standard and meets SIL2/3 functional safety requirements. Provide MID metrology certification certificate, applicable for metrology handover
Even under conditions of temperature changes during the process, accurate measurements can still be made;
HistoROM ®/ M-DAT memory storage unit, capable of recalling instrument settings and measurement values;
IEC 61508 standard certified by T Ü V S Ü D, applicable for SIL2/SIL3 functional safety process monitoring (maximum... minimum... range);
From measuring thin films to electronic components, providing overload protection and functional monitoring;
The quick setup menu allows for quick setting of basic debugging parameters, menu guided operation, and provides advanced fault diagnosis functions;
Optional installation of valve group: and conduct pressure test;
Seamless and independent system integration (HART/PA/FF);
Process links: threads, flanges;
Temperature range: -40 to+125 ° C (-40 to+257 ° F);
Pressure range:+100mbar to+700bar (+1.5 to+10.500psi);
Accuracy error: ± 0.05%, "Platinum type" ± 0.025%;
International explosion-proof protection certification, WHG overflow protection, sanitary certification, sea level certification, SIL;
Supply Voltage | 4...20mA HART |
Measurement accuracy | 0.05% |
Long term stability | 0.05% URL /years |
Process temperature | -40...125 °C |
Ambient temperature | -40...85 °C |
Sensor | 100 mbar...700 bar |
Minimum calibratable range | 5 mbar (0.075 psi) |
Resistance to vacuum pressure | 10 mbar (1.45 psi) |
Maximum range ratio | 100:1 |
Maximum overvoltage limit value | 1050 bar (15.750 psi) |
![]() |
Cerabar PMP71 Digital Pressure Measurement Transmitter Pressure Transmitters For Measuring Liquids And Gases Images |